Flow meter Archives - Page 42 of 76 - Just Measure it

Flow meter

DC excitation

The DC excitation mentioned here includes a constant magnetic field using a permanent magnet and a constant magnetic field excited by a DC current. However, the DC signal voltage induced by the use of a DC magnetic field can easily polarize the electrolyte liquid flowing through the measuring tube, and the resultant signal obtained on […]

DC excitation Read More »

Raw water electromagnetic flow meter

Split electromagnetic flowmeter, on-site display, 220V power supply 50Hz, 4-20mA output (four-wire system), carbon steel body, PTFE lining, 316L electrode, national standard flange connection (not including matching flange, bolts, and nuts), Pressure resistance 1.6MPa, temperature resistance -30~120℃, protection grade IP65, including 10 meters signal line Display: Instantaneous flow m3/hr Totalizer in m3/hr. Accessories choosable: Signal

Raw water electromagnetic flow meter Read More »

The case of liquid metal

The conductivity of liquid metal is several orders of magnitude higher than the conductivity of the best non-metallic conductive liquids. The appearance of the skin effect makes the edge effect of the magnetic field more complicated, and the influence of the eddy current becomes greater when the flowmeter with AC excitation is used. It can

The case of liquid metal Read More »

Differential pressure flow meter design and customization

Key points of customization of differential pressure flow meters: The design and customization of the differential pressure flowmeter are to determine the various parameters of the differential pressure flowmeter according to the on-site process conditions. When customizing a differential pressure flow meter, you should first determine that the fluid conditions meet the following requirements: (1)

Differential pressure flow meter design and customization Read More »

High frequency rectangular wave excitation and programmable pulse width rectangular wave excitation

Advanced electromagnetic flowmeter manufacturers, aiming at slurry fluid measurement and high-speed responsiveness, apply advanced semiconductor components and single-chip computer technology, and develop various high-frequency rectangles relative to low-frequency (1/8 to 1/32 power frequency) Wave excitation (usually around 100Hz, medical blood flow meter measuring human body up to 400Hz) and programmable pulse width excitation electromagnetic flowmeter,

High frequency rectangular wave excitation and programmable pulse width rectangular wave excitation Read More »

AC excitation

AC excitation usually refers to the use of a 50Hz (or 60HZ) sine wave power frequency city excitation sensor. The most important advantage of this excitation method is that it can reduce the polarization of the electrolyte liquid on the electrode. Therefore, the influence of drifting DC interference on the measurement is greatly reduced. Secondly,

AC excitation Read More »

Eddy current generation

We know that metal conductors and conductive fluids in an alternating magnetic field will also generate an induced electric potential like the iron core of an energized iron core coil, and an induced current will appear. These induced currents flow in a vortex around the center of the conductor in the metal conductor and fluid,

Eddy current generation Read More »

Surface Tension

Due to the cohesion between molecules, the free surface of the liquid shows a tendency to shrink. Since cohesion can only be manifested in the range of action with a small radius (approximately 10-7cm), molecules with a large distance from the interface will be offset by the gravitational forces of the surrounding molecules and will

Surface Tension Read More »

Translate »