admin_zero, Author at Just Measure it - Page 241 of 342

admin_zero

Differential pressure measurement of tank level

Open tank (unpressurized) measurement Regarding differential pressure level measurement, there are two main types of storage tanks: open (unpressurized) and closed (pressurized). Open, non-pressurized storage tanks are connected to the atmosphere; there is a clear path from the tank to the surrounding environment, and the air pressure acting on the liquid is equal to atmospheric […]

Differential pressure measurement of tank level Read More »

How to set up measuring instruments for metering grade and non-metering grade storage tanks?

The measurement of storage tanks mainly has two purposes: to control the storage capacity of storage tanks to meet production operations such as oil collection and oil delivery; and to measure tank area inventory, that is, inventory management. The measurement methods for the two purposes are different, and the equipment and selection of instruments are

How to set up measuring instruments for metering grade and non-metering grade storage tanks? Read More »

Grounding and liquid contact of electromagnetic flowmeter

The flow signal of the electromagnetic flowmeter is based on the measured conductive liquid as the reference potential. The conductive liquid in the entire measurement pipe is regarded as a conductor with zero resistance. The two electrodes form a differential signal voltage to the conductive liquid. Therefore, if the signal contact point is unreliable, the

Grounding and liquid contact of electromagnetic flowmeter Read More »

Instruments are regularly lubricated and protected against corrosion

The lubrication cycle should be determined according to the specific situation and mainly includes the following parts: 1. Pneumatic cam deflection valves, pneumatic ball valves, pneumatic butterfly valves, and rotating parts of electric actuators; 2. Protection box, door shaft of the insulation box, and fastening bolts of the junction box; 3. Bolts and nuts for

Instruments are regularly lubricated and protected against corrosion Read More »

Things to note before installing the instrument

1. Before installing the instrument, the process pipeline should be purged to prevent ferromagnetic substances retained in the pipeline from adhering to the instrument, affecting the performance of the instrument or even damaging the instrument. If unavoidable, a magnetic filter should be installed at the inlet of the instrument. The instrument itself does not participate

Things to note before installing the instrument Read More »

Measurement advantages of radar level gauge in acidic environment

Level monitoring of corrosive liquids such as acids is a challenging task among many industrial measurement scenarios. Traditional liquid level measurement technologies, such as float, pressure or capacitive sensors, are often unable to cope with high temperature and highly corrosive acidic media. The radar level gauge shows unique advantages in such an environment. Today we

Measurement advantages of radar level gauge in acidic environment Read More »

Translate »