Level meter Archives - Page 7 of 93 - Just Measure it

Level meter

Submersible Level Transmitter – Design, Installation, and Precautions

1. Introduction The submersible level transmitter is designed for accurate measurement of liquid levels in various industrial applications. Its robust structure and optimized probe design ensure reliable operation in both static and dynamic liquid conditions. The device operates by sensing the hydrostatic pressure exerted by the liquid column and converting it into a standard electrical […]

Submersible Level Transmitter – Design, Installation, and Precautions Read More »

Contact vs. Non-Contact Industrial Instruments: Principles, Advantages, and Applications

1. Introduction In modern industrial automation and precision manufacturing, instruments play a crucial role in measuring, monitoring, and controlling various physical parameters such as temperature, pressure, and level.Based on the measurement method, industrial instruments can be classified into contact-type and non-contact types. Contact-type instruments acquire data by physically touching the target, whereas non-contact instruments measure

Contact vs. Non-Contact Industrial Instruments: Principles, Advantages, and Applications Read More »

Application of Radar Level Transmitters in Diazo Reaction Kettles

In modern industrial production, precise level measurement is not only crucial for enhancing production efficiency but also serves as the foundation for process safety and stability. With technological advancements, radar level transmitters, known for their unique non-contact measurement capabilities, have demonstrated exceptional value in complex industrial environments such as diazo reaction kettles. A diazo reaction

Application of Radar Level Transmitters in Diazo Reaction Kettles Read More »

Application of Guided Wave Radar Level Meter in Liquid Level Measurement of Distillation Columns

In industrial fields such as chemical and petrochemical industries, distillation columns are common separation equipment used to separate components in mixtures based on differences in boiling points or vapor pressure. The efficient operation of distillation columns relies on precise control of the liquid level within the column, as the accuracy of liquid level measurement directly

Application of Guided Wave Radar Level Meter in Liquid Level Measurement of Distillation Columns Read More »

Radar Level Transmitters: Preventing and Eliminating the Impact of Steam and Condensation

1. Introduction In high-temperature or high-humidity industrial processes, steam and condensation can significantly affect the measurement accuracy and reliability of radar level transmitters. Water droplets or condensate films on the antenna surface may attenuate the radar signal, causing unstable readings or complete signal loss. This document outlines proven preventive and corrective measures to mitigate these

Radar Level Transmitters: Preventing and Eliminating the Impact of Steam and Condensation Read More »

Understanding the Real-World Difference Between 0.1% and 1% Resolution Ultrasonic Level Meters

Resolution is one of the most overlooked specifications when selecting an ultrasonic level meter. Yet, it plays a critical role in determining how precisely the instrument can detect changes in liquid level. In this article, we’ll explain what resolution really means, show practical examples, and help you decide whether 0.1% or 1% resolution is right

Understanding the Real-World Difference Between 0.1% and 1% Resolution Ultrasonic Level Meters Read More »

How to Maintain a Submersible Level Transmitter: A Complete Guide for Reliable Measurement

Introduction Submersible level transmitters, also known as hydrostatic level sensors, are widely used for monitoring liquid levels in tanks, wells, reservoirs, and treatment facilities. Whether applied in clean water, wastewater, oil, or corrosive chemicals, proper maintenance is essential to ensure accurate readings and long-term reliability. In this article, we’ll walk you through key maintenance tips,

How to Maintain a Submersible Level Transmitter: A Complete Guide for Reliable Measurement Read More »

Understanding the Differences Between SPST and DPDT Relay Contacts

1. Introduction In industrial automation and instrumentation control systems, the selection of relay contact types plays a critical role in system reliability and control flexibility. Two commonly used types are: SPST (Single Pole Single Throw) DPDT (Double Pole Double Throw) This article compares the structural differences, wiring diagrams, and application scenarios of SPST and DPDT

Understanding the Differences Between SPST and DPDT Relay Contacts Read More »

How to Choose the Right Level Transmitter for Small-Diameter Storage Tanks

Selecting the right level transmitter for small-diameter storage tanks is crucial for accurate liquid level measurement and operational efficiency. With various technologies available, choosing the most suitable option depends on the storage medium, environmental conditions, and required measurement precision. In this article, we will explore the key factors that influence the selection of level transmitters

How to Choose the Right Level Transmitter for Small-Diameter Storage Tanks Read More »

Application Scenarios of Anti-Condensation Ultrasonic Level Sensors

Anti-condensation ultrasonic level sensors are designed to perform reliably in humid, high-moisture, and high-temperature-difference environments. Their ability to prevent signal disruption caused by condensation makes them ideal for various industrial, agricultural, municipal, and logistics applications. 1. Industrial Process Applications in Humid Conditions ● Food Processing Facilities In processes such as can sterilization, sauce boiling, and

Application Scenarios of Anti-Condensation Ultrasonic Level Sensors Read More »