Magnetic flow meter pipe diameters
Magnetic flow meter pipe diameters Read More »
Description LS1206B Propeller Type Current Meter is used to measure hourly average flow velocity on given points. Being light, impact, and portable, this instrument applies to rivers, pipelines, irrigation and drainage channels, hydrological investigation, and runoff experiments. Specification The Rotary Diameter for Propeller: Ф60mm The Hydraulic Thread Pitch for Propeller: H=120mm Minimum Velocity: Vo≤0.06m/s(Normal) Vo≤0.05m/s(Premium)
OPERATION&NAINTENANCE NANUAL LS 1206B PROPELLER TYPE CURRENT METER Read More »
The sanitary electromagnetic flowmeter adopts a new type of sanitary lining material and lining technology, which meets the sanitary requirements of the food industry. At the same time, it adopts a stainless steel shell and a stainless steel clamp connection, which is convenient for the rapid disassembly and cleaning of the electromagnetic flowmeter, so that
Sanitary magnetic flow meter Read More »
An electromagnetic flowmeter is formed by the combination of a transmitter and a flow sensor. The work of the flow sensor is to simply convert the volume flow of the conductive liquid that flows in the pipeline, and into the linear electrical signal. The principle used for conversion is derived from Faraday’s Law of electromagnetic
Magnetic flow meter excitation Read More »
Where:5xDN and 250 are the straight tube section in the front and rear of the flowmeter,100 is the pre-left position for installation of the magnetic filter. Notices on installation instrument Before installation of the instrument, the process lines should be blown off to prevent ferromagnetic substances from staying in pipes from adhering
Installation of intelligent metal tube rotameter flowmeter Read More »
Mass flow meter dimension, flow range, pressure, Zero stability, and Velocity Parameter.
Mass flow meter dimensions Read More »
The principle of density measurement by mass flowmeter. Can mass flow meters measure density? The answer is yes. The principle is explained below: One end of the flow tube is fixed, while the other end is free. This structure can be regarded as a weight/spring system composed of a weight suspended on a spring. Once
Mass flow meter density Read More »
24VDC±10% Power consumption: 7W (basic power supply) 220VAC Power consumption: 10W (additional power supply) The power supply of the essential safety explosion-proof transmitter (secondary meter) is AC 220V/50Hz. Power consumes less than 15W. The power supply of the composite explosion-proof transmitter (secondary meter) is DC 24V. Power consumes less than 15W. Power wires in the
Mass flow meter power supply Read More »
Meter K-Factor is defined as the number of pulses per unit mass or volume at a particular flow rate. Every meter in each turbine contains a K-Factor or a ratio of the pulses per unit of flow. Coriolis flowmeters do not have a fixed K-factor (number of pulses output per unit of flow). The number
Mass flow meters K factor Read More »
Advantages of Coriolis Mass Flowmeters True mass flow measurement. Multi-parameter measurement, while measuring the mass flow, the volume flow, additional temperature, and density can be obtained at the same time. Very high accuracy for mass flow measurements. Highly accurate density measurement. Unaffected by pressure, temperature, and viscosity. Easy to install, clean, and maintain, no inlet
Mass flow meter advantages and disadvantages Read More »