The main sources of electromagnetic flowmeter failures caused by piping systems and related equipment are as follows

Poor installation Not full tube Gas storage in the piping system Constantly inhale gas Flow status changes during use 1. Poor installation Poor installation is manifested in: The flow sensor and the inner diameter of the connecting pipe are incorrectly matched, and the difference is too large. Without the manufacturer’s recommendation, the inner diameter of

The main sources of electromagnetic flowmeter failures caused by piping systems and related equipment are as follows Read More »

electromagnetic flow meter failure caused by environment

1. Strong magnetic field Since it is generally noted to be far away from the strong magnetic field during installation, there are not many cases where the strong magnetic field affects the practice. 2. Strong electromagnetic wave The electromagnetic flowmeter should meet the requirements of electromagnetic compatibility, work normally under the specified radiated electromagnetic field

electromagnetic flow meter failure caused by environment Read More »

Commonly used flow velocity in the pipeline

Average velocity: m/s.  For the reference of the electromagnetic flow meter. Type of fluid Application occasions Type of pipe Average velocity Water General water supply Main pressure pipeline 1.5-3 Low-pressure pipeline 0.5-1 Pump inlet 0.5-2.0 Pump outlet 1.0-3.0 Industrial water Centrifugal pump pressure pipe DN250 0.5-2.0 Centrifugal pump suction pipe DN250 1.5-2.5 Reciprocating pump pressure

Commonly used flow velocity in the pipeline Read More »

Considerations for electromagnetic flowmeter selection

If the primary selection has been determined to adopt the electromagnetic flowmeter measurement method, the instrument selection becomes the specific electromagnetic flowmeter selection, and several factors in the five aspects of the appeal must be reconsidered. However, the focus of consideration has shifted from the selection of instrument varieties to the comparison and selection of

Considerations for electromagnetic flowmeter selection Read More »

Overview of Float Flowmeter

Because of its simple structure, reliable performance, intuitive reading, small and constant pressure loss, approximate linear scale, wide measurement range, convenient maintenance, and low price, the float flowmeter is widely used in flow measurement and control occasions such as liquids and gases. In the application of various types of flow meters in China, it has

Overview of Float Flowmeter Read More »