turbine meter turndown ratio
Turndown ratio is also commonly referred to as rangeability. A turbine flow meter measurement Ratio Standard is 10:1 and has an Option of 20:1.
turbine meter turndown ratio Read More »
Turndown ratio is also commonly referred to as rangeability. A turbine flow meter measurement Ratio Standard is 10:1 and has an Option of 20:1.
turbine meter turndown ratio Read More »
The installation of DN200 Plug-in type target flowmeter. The application is for air. Others application such as air and Chlorine gas.
DN200 Plug-in type target flowmeter Read More »
Calculation of pressure loss of liquid turbine flowmeter To calculate whether the pressure loss has an effect on the process pipelines, the following formula is used: △P=1.2ρ. v2(Pa) △P: PRESSURE LOSS (Pa) P: Medium density (KG/M3) V: Average velocity in Tube (m/s) When the medium under test is liquid, in order to prevent vaporization and
turbine flow meter pressure drop Read More »
The turbine flow meter output signal has the options of 4-20ma, pulse output, or Modbus RS485 communication.
turbine flow meter output signal Read More »
A rotameter consists of a tapered tube, typically made of glass with a ‘float’ (a shaped weight, made either of anodized aluminum or a ceramic), inside that is pushed up by the drag force of the flow and pulled down by gravity. The drag force for a given fluid and float cross-section is a function
Variable area flow meter applications Read More »
Small antenna size, easy to install; Non-contact radar, no wear, no pollution. Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature, and pressure changes. A serious dust environment on the high-level meter work has little effect. A shorter wavelength, the reflection of solid surface inclination is better. The
The characteristics of 26G High frequency radar level meter Read More »
The length and bolt size should contact the factory.
Magnetic flow meter dimensions Read More »
Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to
radar level meter principle Read More »
Description LS1206B Propeller Type Current Meter is used to measure hourly average flow velocity on given points. Being light, impact, and portable, this instrument applies to rivers, pipelines, irrigation and drainage channels, hydrological investigation, and runoff experiments. Specification The Rotary Diameter for Propeller: Ф60mm The Hydraulic Thread Pitch for Propeller: H=120mm Minimum Velocity: Vo≤0.06m/s(Normal) Vo≤0.05m/s(Premium)
OPERATION&NAINTENANCE NANUAL LS 1206B PROPELLER TYPE CURRENT METER Read More »