The liquid turbine flowmeter is a viscosity-sensitive flowmeter. When the fluid viscosity increases, the linear region of the meter coefficient becomes narrower, and the lower limit flow rate increases. When the viscosity increases to a value, even the wireless region. The situation with spiral blades is much better than with straight blades. For liquids, the […]

turbine flow meter viscosity Read More »

turbine meter upstream and downstream requirements

Required Lengths of Straight Runs Flow altering devices such as elbows, valves, and reducers can affect accuracy. See the diagram below for typical flow meter system installation.   The recommended guidelines are given to enhance accuracy and maximize performance. The distance given here are minimum requirements; double them for desired straight pipe lengths. Upstream: allow

turbine meter upstream and downstream requirements Read More »