High frequency rectangular wave excitation and programmable pulse width rectangular wave excitation

Advanced electromagnetic flowmeter manufacturers, aiming at slurry fluid measurement and high-speed responsiveness, apply advanced semiconductor components and single-chip computer technology, and develop various high-frequency rectangles relative to low-frequency (1/8 to 1/32 power frequency) Wave excitation (usually around 100Hz, medical blood flow meter measuring human body up to 400Hz) and programmable pulse width excitation electromagnetic flowmeter, […]

High frequency rectangular wave excitation and programmable pulse width rectangular wave excitation Read More »

AC excitation

AC excitation usually refers to the use of a 50Hz (or 60HZ) sine wave power frequency city excitation sensor. The most important advantage of this excitation method is that it can reduce the polarization of the electrolyte liquid on the electrode. Therefore, the influence of drifting DC interference on the measurement is greatly reduced. Secondly,

AC excitation Read More »

Eddy current generation

We know that metal conductors and conductive fluids in an alternating magnetic field will also generate an induced electric potential like the iron core of an energized iron core coil, and an induced current will appear. These induced currents flow in a vortex around the center of the conductor in the metal conductor and fluid,

Eddy current generation Read More »

Surface Tension

Due to the cohesion between molecules, the free surface of the liquid shows a tendency to shrink. Since cohesion can only be manifested in the range of action with a small radius (approximately 10-7cm), molecules with a large distance from the interface will be offset by the gravitational forces of the surrounding molecules and will

Surface Tension Read More »

Magnetic meter Preparation and debugging before operation

As with the usual meters, after the electromagnetic flowmeter is installed and wired, it should be checked whether the installation and wiring are correct and whether the meter can work normally. It must be emphasized here that for some units lacking experience, the instrument installation and operation personnel should carefully read the relevant technical instructions

Magnetic meter Preparation and debugging before operation Read More »

Gas turbine flow meter General technical requirements

General technical requirements 1. Files The flowmeter should be accompanied by instructions for use. The flow meter that is calibrated periodically should also have the previous verification or calibration certificate. 2. Nameplate and logo (1) The flow meter should have a clear flow direction mark. (2) The flowmeter should have a nameplate. The meter body

Gas turbine flow meter General technical requirements Read More »