Target Flow Meter For Chemical Industry testing regulations

Factory inspection Each flowmeter must be inspected to be qualified before leaving the factory. Only when all inspection items are qualified can the flowmeter be determined to be qualified, and repairs are allowed if there are unqualified items. Timing of type evaluation Type evaluation must be carried out when one of the following conditions exists: […]

Target Flow Meter For Chemical Industry testing regulations Read More »

Target Flow Meter For Chemical Industry Calculation method

Flow coefficient calculation The flow coefficient of the flowmeter is calculated by the formula (1): ·················(1) The flow coefficient is related to the diameter of the measuring tube, the diameter of the target plate, the flow rate of the measured medium, the properties of the measured medium, and the performance of the sensor. It is

Target Flow Meter For Chemical Industry Calculation method Read More »

Target flow meter for chemical industry Basic parameters and performance

Basic parameters and performance Normal working environment conditions Ambient temperature: -35℃~70℃ Relative humidity:10%~95% Atmospheric pressure: 86kPa~106kPa Nominal diameter The nominal diameter of the flowmeter should be selected from the following values, the unit is millimeter (mm) 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500,

Target flow meter for chemical industry Basic parameters and performance Read More »

Target flowmeter Index and Display

Main index and display Index Medium Liquid, Gas ,Steam, and LPG Caliber Pipe type 15~300mm Clamp type 15~600mm Plug type100~2000mm Pressure 0.6~10MPa 0.6~42MPa 0.6~42MPa Medium Temperature -196℃~+450℃ ( Confirming the temperature range before purchase) Precision ±0.2% ±0.5% ±1.0% ±1.5% ±2.5% Range 1:03 1:05 1:10 1:10 1:10(Steam) Compensation Temperature compensation; Pressure compensation Repeatability 0.1%~0.08% Power Supply

Target flowmeter Index and Display Read More »

Target flowmeter no pulse

There are three main possibilities: One is that the sensor has no output. Solution method:For flowmeters with batteries, check whether the batteries are installed securely, whether the contacts are good, and whether the batteries are electricity. For the external power supply, check whether the connection between the connecting wires is intact and whether the wires

Target flowmeter no pulse Read More »

Grounding methods of electromagnetic flowmeters-Essential for accurate flow measurements

The following info is from Krohne Webinar, Zero Instrument prepare. Necessity of Grounding Grounding: Protective Ground (PE) & Functional Ground (FE) Methods of conventional Functional Ground (FE) Problems with conventional Functional Ground (FE) Improvements in conventional Functional Ground (FE) Summary Necessity of Grounding Electromagnetic flow measurement (Faraday’s Law) ●The induced signal voltages are very small:

Grounding methods of electromagnetic flowmeters-Essential for accurate flow measurements Read More »

The sanitary clamp-type target flowmeter

1.General Introduction It adopts mature and reliable force weighing sensor technology, which can integrate the flow rate and flow (or optimize the temperature and pressure detection of the working condition) according to the characteristics of the working condition, which fully reflects the integration of today’s electromechanics High-tech and cost-effective of chemical products. The data processing

The sanitary clamp-type target flowmeter Read More »