vortex flow meter upstream and downstream requirements - Just Measure it

vortex flow meter upstream and downstream requirements

Required Lengths of Straight Runs

Flow altering devices such as elbows, valves, and reducers can affect accuracy. See the diagram below for typical flow meter system installation.

## Required Lengths of Straight Runs Flow altering device such as elbows, valves and reducers can affect accuracy. See diagram below for typical flow meter system installation

The recommended guidelines are given to enhance accuracy and maximize performance. The distance given here are minimum requirements; double them for desired straight pipe lengths.

  • Upstream: allow a minimum straight pipe length at least 10 times the internal diameter of the pipe. For example, with the 50mm pipe, there should be 500mm of straight pipe immediately upstream. The desired upstream straight pipe length is 1000mm.
  • Downstream: allow a minimum straight pipe length at least 5 times the internal diameter of the pipe. For example, with the 50mm pipe, there should be 250mm of straight pipe immediately upstream. The desired upstream straight pipe length is 500mm.
Share This Story, Choose Your Platform!

Contact Us

    Please prove you are human by selecting the house.