Level meter Archives - Page 70 of 89 - Just Measure it

Level meter

How to find out the faults in the guided wave radar level meter

Although not as widely used as non-contact radar level meters, guided wave radar level meters can occasionally be seen in all walks of life. Therefore, it is very necessary and crucial to understand the common faults of guided wave radar level meters as well as clear inspection ideas. Radar level meter faults can basically be […]

How to find out the faults in the guided wave radar level meter Read More »

Several considerations when installing a guided wave radar level meter

Guided wave radar level meter selection, need to consider many factors, such as working conditions, media characteristics, etc. In fact, the guided wave radar level meter installation, also need to consider a lot, especially a few considerations are necessary to know. Do not install the steel cable too loosely when installing the guided wave radar

Several considerations when installing a guided wave radar level meter Read More »

How to install a radar level meter in a storage tank with a heating coil

How to install a radar level meter in a storage tank with a heating coil. Next, we start with a case study to understand the influence of the heating coil on the radar level meter measurement. Case. Client name: A chemical plant Service location: Ningxia Detailed site conditions (temperature, pressure, medium): liquid alkali, hydrochloric acid,

How to install a radar level meter in a storage tank with a heating coil Read More »

Analysis of common problems in the selection and installation of radar level meters for sulphuric acid storage tanks

Sulphuric acid storage tanks occupy an important position in the smelting industry, and the accuracy of the liquid level is directly related to the continuity of smelting production and the safe and smooth operation of automated smelting production. Therefore, when selecting and installing radar level meters, the following common problems should be noted. First, pay

Analysis of common problems in the selection and installation of radar level meters for sulphuric acid storage tanks Read More »

How to solve problems when installing a guided wave radar level meter

Non-contact radar level meter with a small antenna size for easy installation. However, wave-guided radar level meters are contacted measurement methods, and when installing them, not only the flange part of the meter head must be considered, but also the antenna part. Firstly, is it OK for the cable to wobble? The answer is of

How to solve problems when installing a guided wave radar level meter Read More »

Analysis of radar level meter data jumps through typical cases

Radar level meters often encounter data jumps in the course of use. How is this caused? How can this be solved step by step? Next, let’s look at a case study. Case study. Service location: Henan Service time: September 2021 Site details of working conditions (temperature, pressure, medium): room temperature and pressure, measuring coal lumps,

Analysis of radar level meter data jumps through typical cases Read More »

Radar level meter installation and maintenance needs to pay attention to several aspects

Radar level meter selection is crucial, and directly related to the accuracy of the measurement, the efficiency of the work can be improved. Radar level meter installation and maintenance, equally important, is also related to the accuracy of the measurement or not, the level meter life length. Today, the radar level meter installation and maintenance

Radar level meter installation and maintenance needs to pay attention to several aspects Read More »

How to make waveguide tubes to better meet the requirements of radar level meter installations

In many cases, the radar level meter is installed inside the tank and does not meet the accuracy requirements at all. In order to gather microwave pulses and reduce scattering, one of the ways to do this is to install them inside a waveguide tube, especially where there are large fluctuations in the liquid level

How to make waveguide tubes to better meet the requirements of radar level meter installations Read More »