Blog - Just Measure it
Flow meter

Vortex flow meter fault- 485 communication cann’t connected

485 communication cannot be connected The parameter confirmation function is selected for the 485 functions refers to the manual The...
Read More
Flow meter

Vortex flow meter fault – abnormal current output

The current output is not normal (1) Three-wire current, current output abnormal ● Pay attention to the wiring: 24V, COM,...
Read More
Flow meter

Turbine flowmeter failure-Abnormal temperature/pressure display

Abnormal temperature display ● If the temperature display is abnormally high when the battery is powered, the battery is dead...
Read More
Flow meter

Turbine flowmeter failure – flowmeter display too fast or too slow

The flow meter displays fast ● Whether the customer has set the parameters ● If the installation is in accordance...
Read More
Flow meter

Vortex flow meter fault-No equivalent output from the meter

● Pulse mode and pulse equivalent can be modified in the parameters, refer to the manual for details ● Pulse...
Read More
Flow meter

Vortex flow meter fault – no pulse output

No pulse output from the flow meter. ● Pulse mode and pulse equivalent can be modified in the parameters, refer...
Read More
Flow meter

Electromagnetic flow meter failure-no pulse output

Fault point: Converter Test tool. Verification scheme. 1. Confirm if there is a pull-up resistor at the site 2. Whether...
Read More
Flow meter

Electromagnetic flow meter failure – inaccurate flow (converter)

Fault point: inaccurate flow Fault point: Converter Troubleshooting solution. Test the internal parameters of the meter head for the correctness...
Read More
Flow meter

Electromagnetic Flow Meter Failure-Inaccurate flow (sensor)

Fault point: SensorTroubleshooting solution.Correct installation positionTest result.The mounting position does not meet the requirementsTreatment solution.Replace the mounting position (Appendix 5)Appendix...
Read More
Flow meter

Electromagnetic Flow Meter Failure-Without 485 communication

Fault point: Converter Detection tool: Test software Troubleshooting solution. 1. Confirm that the communication protocol matches the meter head 2....
Read More
Flow meter

Electromagnetic flow meter failure-No display after power-on

Fault phenomenon: No display after power onFault point: ConverterDetection tool: MultimeterVerification program.1. Detect whether the site voltage is normal2. Detect...
Read More
Flow meter

Gas turbine flow meter fault analysis – no display when there is a flow

Whether the customer has moved the parameters.If it is the signal line of the coil (D4 type is not), use...
Read More
Flow meter

Electromagnetic flow meter failure – unstable flow

Fault point: Sensor Verification program. 1. flowmeter installation position is correct 2. Whether there are media covering the electrode 3....
Read More
Flow meter

Electromagnetic flow meter failure – no fluid flow in pipe with flow indication (transducer)

Fault point: no pipe running with flow indication Fault point: Converter Troubleshooting solution. Test whether the parameter setting of the...
Read More
Flow meter

Electromagnetic flow meter fault 4-20mA inaccurate

Fault point: Converter Test tool: Multimeter Checking solution. 1. The measurement range of the flowmeter is consistent with the user's...
Read More
Flow meter

Electromagnetic flow meter failure-System alarms (converters)

Fault point: Converter Inspection tool: spanner / multimeter Checking program. 1. Check if the wiring between the meter head and...
Read More
Flow meter

Electromagnetic flow meter No 4-20mA output Treatment solutions

Fault point: Converter Test tool: Multimeter Solution: Remove IOUT and COMM wiring, use a multimeter to detect 4-20mA output between...
Read More
Flow meter

Temperature and pressure compensated vortex flowmeter wiring diagram

Two-wire 4-20mA current output wiring instructions Three-wire 4-20mA current output wiring instructions Wiring instructions for the pulse output function Wiring...
Read More
Level meter

How to install high frequency radar level meters in different shaped storage tanks

The RD90X series 26G HF radar level has a small antenna size for easy installation; non-contact radar, no wear, and...
Read More
Level meter

a waveguide tube for radar level meters

Many of you have questions about the need for a waveguide tube for radar level meters, which are usually used...
Read More
1 46 47 48 49 50 70