Supplying a Corrosion-Resistant Level Switch for Hydrochloric Acid Application - Just Measure it

Supplying a Corrosion-Resistant Level Switch for Hydrochloric Acid Application

Background
In mid-2025, a leading engineering and supply company in Thailand approached us with a requirement for a replacement level switch for one of their chemical process clients. The existing level switch was installed in a tank containing 5% hydrochloric acid, and their team needed a reliable, corrosion-resistant solution compatible with their existing control system.

Client Challenges

  • The process medium was weak hydrochloric acid, requiring a wetted material with excellent chemical resistance.

  • The existing wiring system was 3-wire (L, N, PE), designed for direct relay coil switching without a NAMUR isolator.

  • The client required a quick delivery window to avoid process downtime.

Our Solution
After analyzing the application details and wiring diagram, we proposed the Ring-11 Tuning Fork Level Switch with the following configuration:

  • Output Type: Relay Output (Dry Contact, compatible with direct load switching)

  • Power Supply: AC220V or DC24V

  • Wetted Parts: 316L Stainless Steel with ECTFE/PFA coating for superior corrosion resistance

  • Process Connection: 2” ANSI 150RF Flange

  • Probe Length: 300mm

  • Housing: Anti-corrosive Nylon (IP66 rated)

We provided a clear wiring diagram tailored to their control panel logic, ensuring full compatibility with their existing setup without requiring any system modifications.

Outcome
Order placed and payment received in July 2025
Production and shipment scheduled within 10 days via UPS Express
✅ Client appreciated the technical support and fast turnaround, paving the way for further collaboration on future instrumentation projects.