Introduction

Terminal resistors play a crucial role in ensuring reliable sensor signal transmission, especially in industrial and field applications where long-distance communication is involved. They are primarily used for impedance matching, minimizing signal reflection, and enhancing data integrity. Improper use of terminal resistors can lead to signal degradation, increased noise, and communication failures. This article provides an in-depth guide on selecting, installing, and troubleshooting terminal resistors in sensor-based communication systems.

1. Understanding the Function of Terminal Resistors

Terminal resistors are typically used to:

  • Prevent Signal Reflection: When a signal propagates through a transmission line, impedance mismatches at the ends can cause reflections that interfere with data integrity.

  • Ensure Impedance Matching: Properly chosen resistors match the characteristic impedance of the transmission medium (e.g., twisted-pair cables), minimizing signal loss.

  • Reduce Electrical Noise: Resistors help suppress unwanted interference, particularly in high-frequency communication environments.

2. Choosing the Right Terminal Resistor

a. Selecting the Correct Resistance Value

The resistor value should match the characteristic impedance of the communication medium:

  • RS-485 Bus: Typically requires 120Ω terminal resistors at both ends of the differential pair (A and B lines).

  • CAN Bus: Standard practice is to install 120Ω resistors at both ends of the network to maintain a total impedance of 60Ω.

  • Ethernet (Coaxial and Twisted Pair): Uses termination resistors depending on the physical layer design, usually 50Ω for coaxial cables.

b. Considering Power Dissipation

  • The resistor should have an appropriate power rating to avoid excessive heating.

  • Power dissipation is given by P = V²/R, where V is the signal voltage, and R is the resistance.

  • Typically, ¼-watt resistors suffice for most signal lines, but higher wattage may be necessary for power-intensive applications.

c. Choosing High-Quality Resistors

  • Low Tolerance (1% or better): Ensures consistent performance and prevents variations that might cause impedance mismatches.

  • Temperature Stability: Resistors with low temperature coefficients maintain performance in varying environmental conditions.

  • Durability: Choose moisture-resistant and oxidation-proof resistors for outdoor or industrial applications.

3. Proper Placement of Terminal Resistors

a. Where to Install the Resistors?

  • Always place terminal resistors at the farthest ends of a communication network.

  • For daisy-chain configurations, ensure resistors are placed at both extremities and not in between.

b. Parallel vs. Series Connection

  • Terminal resistors are typically placed in parallel across differential signal lines (e.g., between A and B in RS-485 or CAN).

  • Some systems may require split termination (two resistors with a capacitor in between) for enhanced noise immunity.

4. Common Issues and Troubleshooting

a. Communication Failures Due to Incorrect Resistance

  • If resistance is too high: Signal reflections increase, causing data corruption.

  • If resistance is too low: The bus load increases, potentially causing signal attenuation.

b. Excessive Power Consumption

  • Resistors with a low resistance value can lead to excessive power dissipation and increased power consumption.

c. Noise Interference and Signal Distortion

  • Ensure shielded cables are used where applicable.

  • Use proper grounding techniques and check for ground loops that may impact performance.

5. Special Considerations for Low-Power Systems

  • Low-power devices may require switchable termination resistors to conserve energy when communication is idle.

  • Alternative termination techniques, such as active termination, may be used in power-sensitive applications.

Conclusion

Proper selection and installation of terminal resistors are vital for maintaining signal integrity in sensor-based communication systems. By following the best practices outlined above, engineers can ensure reliable, interference-free data transmission, whether using RS-485, CAN bus, or other wired communication standards. Always consider resistor value, power rating, placement, and environmental factors to optimize performance in real-world applications.