Gas turbine flow meter fault analysis - no display when there is a flow - Just Measure it

Gas turbine flow meter fault analysis – no display when there is a flow

  • Whether the customer has moved the parameters.
  • If it is the signal line of the coil (D4 type is not), use a magnet against the base and slide it left and right to get an instantaneous flow.
  • Ask the customer if there is a signal that is not present after repeatedly turning the meter head, if so, the signal has fallen out.
  • If the main card is stuck, use a screwdriver or other tool to move it. If the rotation is not flexible, the bearings are worn out.
Share This Story, Choose Your Platform!

Contact Us

    Please prove you are human by selecting the flag.

    Leave a Comment

    Your email address will not be published. Required fields are marked *